The PMG-60 was designed primarily for batch-type washers and, because of its low rating, may be allowed to exhaust directly into the room in compliance with NFPA 54. 17 sheet pans or 34 hotel pans on 1.5" (38 mm) centers. Learn how Hatco and our partners collect and use data. Flav-R 2-Go Floor Mount Pizza Locker System. There's a cheaper alternative, too - to put a disk of compatible material between the cook top and the pan, but this is an inelegant solution and defeats most of the benefits of using induction! Are slide mount brackets available in lieu of legs on ALL Booster Water Heaters, and is there an extra charge? There are no recorded cases of any injury (or harm done to a pacemaker user) in all of that time. What is the warranty on Flav-R-Savor Tall Humidified Holding Cabinets? The drain makes clean up easier, especially when used wet. There are currently four (4) different standard size Remote Control Enclosures (RMBs) shown in the current Hatco literature. What key information is required when sizing a Booster Water Heater to a dishwasher? They have to withstand the impact from a 1.2-lb. When should gas vs. electric be considered for a Booster Water Heater? The National Fuel Gas Code NFPA 54 allows all Booster Water Heaters to vent into the room provided that certain overall conditions exist. The order should specify that the Booster Water Heater is for a low temperature application, and the factory will pre-set the thermostat to 140F (60C). What would be the proper Remote Control Enclosure (RMB) for a GRAHL-48D Glo-Ray Dual Aluminum Infrared Strip Heater (Foodwarmer) with Lights in 120 volt with infinite controls and indicator lights? Charts are provided in the manuals to help achieve compliance with AGA's limits for our models. They are also available with manifold drains and auto-fill as options. Excerpt as permitted in 7.2.2 through 7.2.6, all gas utilization equipment shall be connected to venting systems. Can the Heated Well be equipped without a drain? (Note that an elbow is equivalent to five [5] linear feet of pipe.) A Remote Control Enclosure is an aluminum box specifically designed to hold toggle switches, infinite controls and/or indicator lights when these controls are NOT mounted on the Strip Heaters themselves. The unit would have to be ordered with some sort of legs (i.e., C-legs or T-legs). Can Remote Control Enclosures (RMBs) for Strip Heaters (Foodwarmers) be painted? Please specify mounting option when ordering. One (1) year parts and labor, two (2) years on burnout or breakage of the air and water element. Which merchandising cabinet and what settings do you recommend? Yes. What is the height range of the optional stainless steel adjustable legs for Strip Heaters (Foodwarmers)? Hatco offers an auxiliary hood that can be placed directly over the PMG-60 that will direct flue gas products to the rear of the Booster Water Heater. No. Yes, the Heated Well can be used with or without a drain. Yes, Hatco offers UR Heated Wells in all sizes: -FUL, -43, -7QT and -11QT. Day-old bread at room temperature that has been allowed to breathe works best. The fundamental difference is the S-12 Imperial Electric Booster Water Heater has a 16 gallon (60 liter) tank, and the C-12 Compact Electric Booster Water Heater has a 6 gallon (23 liter) tank. All other kW models cannot be field converted. Where is the cord grip located on the Flav-R-Savor Tall Humidified Holding Cabinet? The thermostat that controls the surface temperature is designed to allow the surface to get up to 170F - 180F (77C - 82C). This is explained in the following excerpt: EXCERPT FROM ANSIZ223.1/NFPA 54 7.2.1 Connection To Venting Systems. Can I convert an electric Booster Water Heater from single-phase to 3-phase? if a pan has been heating on the top for a long period). The internal temperature of the Thermo-Finisher varies; however, this is not important in regard to its ability to perform. 2022 Hatco Corporation. Loosen and remove the acorn nuts; then remove the bottom assembly. Only 6, 7 and 9kW electric Booster Water Heaters can be field converted to single-phase (units are shipped 3-phase open delta). NFPA 54 and local codes should be checked to be sure they don't take precedence. What type of material and finish are used in C-leg and T-leg stands for Strip Heaters (Foodwarmers)? What is the method of shipment for Hatco Booster Water Heaters? The height or thickness is 3.5" (89 mm). The tandem element charge would be assessed twice: once for the 2nd, and again for the 3rd element. What kind of construction is used on the Modular Heated Wells? What is the advantage of using the drain in a Heated Well? The mineral molecules are unable to join together, so scale is unable to form. Are they really up to the task? 800-558-0607 / The depth with standard 3" (76 mm) spacing is 15" (381 mm), and with optional 6" (152 mm) spacing is 18" (457 mm). Induction is generally faster than gas and heats the whole thickness of the bottom of the pan at the same time - not just from underneath. 4) Heavy-duty 16 gauge stainless steel tubular frame for stability and durability of the cabinet. Proofing is typically done in the 90F - 95F (32C - 35C) range. The flat surface of the GRSBF, available in hardcoat or stainless steel, allows for pans to overhang onto the counter if necessary. Induction cooktops are anywhere from 80% to 95% (depending on how it's measured), but as a rule of thumb, an 1800W induction unit is the equivalent of 16,000 BTUs of gas. Can the PMG-100 & PMG-200 Powermite Gas Booster Water Heater be vented outdoors? Yes, the Heated Well can be ordered with or without a drain. The Heated Wells perform better when used wet because they transfer heat better. Instead, they stand for Recognized, with Thermostat and Recognized with Infinite Switch, respectively. When do you use a low watt Heated Well vs. high watt Heated Well? Remote Control Enclosures can be mounted on a wall or under a counter but should always be mounted away from any heat source. Is it necessary to put distilled water in a GRHD or GRCD Glo-Ray Heated Display Case? What control options are available on "standard" Heated Wells? What is the difference between a thermostat, rheostat and an infinite control? Does it matter? When do you use a high watt Heated Well vs. low watt Heated Well? Tell me about venting the PMG-100 & PMG-200 Powermite Gas Booster Water Heater. The higher the ferrous (iron) content, the better. Induction units are a non-continuous load, which is why an 1800W unit is supplied with a NEMA 5-15P molded plug, and can be used on a 15A circuit. and receive the latest Hatco and industry updates. View and filter our Hatco FAQs to find the answer you're searching for. The GRSB is recessed about 3/4" (19 mm) below the counter. When should I use the Ultra-Glo Strip Heater (Foodwarmer) for foodwarming? HL - represents Glo-Rite Display Lights. What relative humidity can be achieved in the Flav-R-Savor Tall Humidified Holding Cabinet? The number following the letter sequence represents the width (length) of the housing in inches. Why use day-old bread in a Conveyor Toaster? How are the PMG-60, PMG-100 & PMG-200 Powermite Gas Booster Water Heaters different? All Compact and Imperial Electric Booster Water Heaters also include a stainless steel front panel, a powdercoated silver gray hammertone body and a black base. Can the PMG-60 Powermite Gas Booster Water Heater be vented outdoors? Is there any concern about mounting non-insulated Hatco Heated Wells into a countertop made of Corian or other combustible surfaces? UR Heated Wells are shipped without a conduit and the controls are mounted to a control faceplate (control box not included). Please remember to specify RT (thermostat) or RN (infinite) for the controls. A 1-, 2- or 3-well unit has a control box and bezel with 1, 2 or 3 thermostatic controls contained within it. The cooking and finishing that is done in this oven is done as a result of the infrared energy that is coming from above and below the food product. Exhaust temperature is approximately 200F (93C) at the outlet of the Booster Water Heater. The GRSBF has a completely flat surface, flush with the countertop. What types of controls are available on Hatco Modular Heated Wells? Cord and plug sets can be furnished provided the Strip Heater meets the following requirements: it must be a single housing only, with or without lights (duals are not allowed); the housing must be 72" (1829 mm) or less in width (longest dimension); the Strip Heater must be 120 volt; and the Strip Heater must be mounted as a portable unit (i.e., C-legs or T-legs). In extreme cases, where there are more switches than will fit in one, a specially sized Remote Control Enclosure will be recommended. The flue gas may be directed to exhaust behind the counter or dishwasher or up into a nearby ventilation/exhaust hood. They are also available in all standard wattages, with and without drains. 208 volt and 240 volt Booster Water Heaters up to 18kW, and 480 volt in 4kW and 5kW Compact Electric Booster Water Heaters, can be ordered in single phase. Use the energy cost worksheet on our website to calculate energy costs per year, and compare to unit cost. All Hatco Booster Water Heaters come in either 208, 240 or 480 volt and must be hardwired. For example: you might place an elbow at the hood exit, run four (4) feet, then place a second elbow behind the warewasher with a six (6) foot vertical vent tube to exit near the condensate hood. How does your optional Blended Phosphate Water Treatment System work? 414-671-6350, Subscribe to our Newsletterand receive the latest Hatco and industry updates. You can only install the cord when the unit is going to be used in a "portable" application. When you order slide mounting brackets, you will not receive legs with your Booster Water Heater. Unlike a conventional oven, the temperature of the air in the cabinet is not what does the cooking in this type of device. What do I have to know about gas Booster Water Heater ventilation? On many of the longer Glo-Ray Strip Heaters, it is not uncommon to have three (3) elements mounted end-to-end within a single housing. Some helpful suggestions appear in the manuals; however, it is the installer's responsibility to meet the applicable venting system standards. Mini-Compact = 3.2 gallons (12 liters). Are the Heated Wells easy to install and service? UR Heated Wells are models that are recognized as components to be used in someone elses appliance. Infinite controls are negatively effected by heat. No. What other options are available for the Flav-R-Savor Tall Humidified Holding Cabinet? No. The hub allows for easier installation of flexible conduit during Strip Heater installation. Sure, they do this in a different way to gas or electric, but they still heat the pan - not the food. With regard to VOLTAGE, are Hatco electric Booster Water Heaters field convertible from 208 volt to 240 volt or 480 volt, and vice versa? Simplify and improve the takeout experience. What is the highest temperature the Hatco Heated Well can reach when filled with water? Hatco has a two (2) year warranty on Heated Well heating elements. What are the dimensions of each box, excluding switches? All Rights Reserved The Hatco drain size is 3/4" (19 mm) in diameter, 50% larger than the competition, which is only 1/2" (13 mm). I can't afford to use distilled water in my Flav-R-Savor Holding & Display Cabinet. RMB-14AA or AB include an electronic infinite control for very precise control of the Strip Heaters. This type of control is commonly used to control elements on electric ranges. There is a small standard control with a wire guard and small bezel. The height or thickness is 3.5" (89 mm). The choice is yours. The LWCO is automatically reset when the water level is safe. We have disabled all cookies for website and ad personalization, on and off of hatcocorp.com, as well as analytics and measurement. Models are available in 120, 208 and 240 volt. What are the basic dimensions of a Glo-Ray Designer Aluminum Infrared Strip Heater (Foodwarmer), model GR2AH-48? What are the basic dimensions of a Glo-Ray Narrow Infrared Strip Heater (Foodwarmer), model GRN-36? Those glass tops on the induction units don't look very strong. What is the tank capacity of the various Booster Water Heaters? What is the internal temperature of the Thermo-Finisher? If additional hot water is needed (during periods of high demand), the next level of heating elements come on and heats. The Hatco Modular Heated Wells and bezels are all 300 series stainless. Can anybody install a gas Booster Water Heater? Can Modular Heated Wells have drains with individual shut-offs? Why would an auxiliary hood be installed for a PMG-60 Powermite Gas Booster Water Heater? Does the Thermo-Finisher need to be placed under an exhaust hood? This includes two (2) infinite controls for the heating elements, two (2) indicator lights and one (1) toggle switch for the incandescent lights. Hatco uses voltage specific to electrical components in much of our equipment. The vent hood is approved for a 20 linear foot run. An infinite control can be used in lieu of the standard on/off toggle switch. It's true though that copper and all aluminum pans will not work. Check with your local inspectors for final clarification. The coupling allows you to use one of the rotating racks in non-motorized cabinets. When ordering extra leads on UR Heated Wells, what do I need to know? Insulated Heated Wells will hold heat better and longer for greater holding efficiency and better energy conservation. What is the highest temperature the Hatco Heated Well can reach when running dry? Full-size Heated Wells are also available in insulated versions that can be top mounted (HWBI-FUL) or bottom mounted (HWBIB-FUL) in a similar fashion. THEY SHOULD NOT BE ATTACHED TO THE STRIP HEATER! Can you get a heavy-duty transport package for a Flav-R-Savor Tall Humidified Holding Cabinet? P: What would I put into a Hatco Heated Well? Because of this, it is recommended that the heater be left ON at all times when the outside temperature is below 32F (0C) to counteract the unlikely occurrence of cold air migrating into the vent pipe. How far can I vent the PMG-60 Powermite Gas Booster Water Heater? 2) If the UR unit has an infinite control, the extra lead wire is for the connection between the control box and the Heated Well. UR units are commonly purchased by fabricators. All other Booster Water Heaters must be ordered specifically for single-phase or 3-phase, and CANNOT be converted in the field. The Booster Water Heater must be within five (5) linear feet of the dishmachine. What is the function of the Booster Water Heater's low water cut-off? It cycles the Strip Heater on and off frequently, based on the setting. Sizing charts are available in our price list and on our website. Can one Strip Heater (Foodwarmer) with multiple switches, such as a dual with tandem elements, have more than one Remote Control Enclosure (RMB)? In truth, any magnetic pan will work. The depth is 6" (152 mm). The top mount has three options: studs, holes or EZ lock mounting hardware. The low watt Heated Well would be used to limit circuit size in multi-unit applications. The heat is more evenly distributed, too. (Note that an elbow is equivalent to five [5] linear feet.) What are my mounting options on Hatco Modular Heated Wells? This ensures that all pans are always full of water - even when evaporation can become a big issue. 6' (1829 mm) capillaries are available. The wire slides are cold rolled steel that are chrome plated. What standard features are included with Compact and Imperial Electric Booster Water Heaters? Insulated Heated Wells are available only in the -FUL size and can be ordered in top or bottom mount configurations. The formula to figure kW of the Booster Water Heater needed to sanitize at 180F (82C) is: GPH x F Temp Rise/400 = kW required (LPH x Celsius Temp Rise/840 = kW required). The infrared energy is absorbed by the food, causing the food to heat up. What is the difference between the GRSB and GRSBF Glo-Ray Heated Shelves, and why? Proud partners of: Where any or all of this equipment is installed so the aggregate input rating exceeds 20 BTU per hour per cubic foot (207 watts per cubic m) of room space in which it is installed, one or more shall be provided with venting systems or other approved means for removing the vent gases to the outside atmosphere so the aggregate input rating of the remaining unvented equipment does not exceed the 20 BTU per hour per cubic foot (207 watts per cubic m) figure. Since a toggle switch can handle 15 amps, an infinite control cannot always be field retrofitted in place of a toggle. There is an option for a recessed control with a 10 degree slant for easier visibility. What material are the universal slides in the Flav-R-Savor Tall Humidified Holding Cabinet made of? The low-water cut-off (LWCO) is a protective device designed to shut off power to the heating elements, thus preventing burnout should the water level decrease in the Booster Water Heater tank. Booster Water Heaters are available with 400 series stainless steel body and base (resists rusting from salt air), with stainless steel flanged legs for deck mounting. The FSDT is a larger, taller cabinet, constructed with aluminum extrusions, and features fluorescent lighting on the side posts to provide complete illumination. The lead time is generally 3-4 working days from date of order entry. Why would I want an insulated Heated Well. The food is in contact with the hot pan and is heated or cooked in entirely the normal way. What are the basic dimensions of a Glo-Ray Designer Dual Aluminum Infrared Strip Heater (Foodwarmer), model GR2AH-48D? Yes, Hatco uses EZ lock mounting hardware to provide quick installation. Can you field convert the Flav-R-Savor Tall Humidified Holding Cabinet into a two-door unit? What is the safest temperature to hold food? Surely that's not enough to cook? What is the pre-heat time for Flav-R-Savor Tall Humidified Holding Cabinets? Yes, the transport package includes: stand-off handles, full perimeter bumpers, a transport locking latch and heavy-duty 5" x 2" (127 mmx51 mm) casters. GRN - "N" indicates narrow models only 4" (102 mm) deep. Gas burners are typically only 35-45% efficient (which is why commercial kitchens using gas are often so hot). "D" added to model means the unit is a dual warmer made of two (2) single units side-by-side with either a 3" or 6" (76 mm or 152 mm) spacing in between each housing. A kit of blank orifices is available to allow you the flexibility to comply with the specific altitude regulation at your installation. Are there specific electric Booster Water Heaters that can be wired in single-phase? The depth is 9" (229 mm). You can stand on the ceramic glass and it will not break. Is there an upcharge for pass-through models of the Flav-R-Savor Tall Humidified Holding Cabinet? Easy! This can be ordered in any length in 1 (305 mm) increments. Hatco uses a two letter suffix used to identify UR (Underwriter Laboratories Recognized) units. (EZ lock mounting hardware is the default.). Beyond this length, consult a ventilating specialist to provide appropriate means to move the exhaust farther. There is a low temperature sizing chart in the Hatco Price List or on the website to verify sizing. Induced draft venting was employed to allow the customer to more readily comply with NFPA 54 when these higher ratings are added to the other appliances in the kitchen. What type of bread should I use in a Conveyor Toaster? Where the room or space in which the equipment is installed is directly connected to another room or space by a doorway, archway, or other opening of comparable size that cannot be closed, the volume of adjacent room or space shall be permitted to be included in the calculation. Induction cooktops heat the pan. The depth is 9" (229 mm). Hatco Modular Heated Wells can only be top mounted. If customers want to install individual shut-off on each drain (rather than manifold), they can order individual shut-offs as an accessory and install them on site. The maximum amperage that an infinite control can handle is 12.2 amps. Hatco Wells are made with 1 mm (.039") thick material, about 10% thicker than the competition. Do you recommend installing a check valve on the inlet side of the Booster Water Heater? In some cases performance will suffer or damage to the unit can occur if the wrong voltage is applied. Note this does not apply in Canada, where the rule is different. What are the basic dimensions of a Glo-Ray Dual Aluminum Infrared Strip Heater (Foodwarmer), model GRAH-48D? (The factory should be consulted in these cases.). In this situation, the switches are attached to a plate that is designed to be mounted to a standard electrical junction box. Find out more here. Is there an upcharge for all stainless doors on a Flav-R-Savor Tall Humidified Holding Cabinet? Mount Hatco controls vertically at least 6" (152 mm) away from the Heated Well and at least 3-1/2" (89 mm) from combustible surfaces. To price, subtract the standard rack price and add the price of the replacement rack. What do I need to know if I want to operate a gas Booster Water Heater at high altitudes (higher than 2000 feet [610 m] above sea level)? No "H" means standard wattage (standard heat). Can I put a GRSB/GRSBF Glo-Ray Heated Shelf into a laminate or Corian countertop? Any adjoining room it runs through must be the same temperature as the kitchen. What gauge stainless steel are Hatco Wells? This will obviously be affected by how many times you go in and out of the Flav-R-Savor Tall Humidified Holding Cabinet. Yes, you can substitute any of the applicable racks. Can I order a Glo-Ray Strip Heater (Foodwarmer) with a cord and plug attached? No, so long as they use the mounting kit for non-combustible surfaces to insulate the Heated Well from the countertop surface. Hours: 7:00 am - 5:00 pm (CT) 3) Full height Lexan door as standard. Can the Flav-R-Savor Tall Humidified Holding Cabinet be used as a proofer? For example, if you had a 5-pan well - all five (5) pans would be drained by opening the single manifold 1" (25 mm) drain that connects all five individual drains. It reduces the voltage going to the appliance, which serves to turn it down. I'm not sure if I have a 208 volt or 240 volt Conveyor Toaster. The width (formerly known as length) is 48" (1219 mm). Already prepared hot food (NOTE: The Heated Well is NOT a rethermalizer). Why can't I get infinite controls mounted on my dual Strip Heater (Foodwarmer)? Consider installation and maintenance costs. No, there is currently no stacking kit available for this unit. A low to medium humidity setting, accompanied with moderately high heat, will provide the best result. The only lubrication needed on a Toast-Qwik Conveyor Toaster would be on the bearing that accommodates the cooling fan in the back of the TQ-300 and TQ-700 models (part number for a tube of lubrication is 05.01.018.00). All HWBs have remote controls. What is the warranty on Booster Water Heaters? Toasting of coated products is not recommended. It should be ordered when extended lead wire is specified. Ask your Hatco Representative for an energy cost comparison. I heard that you had to spend a lot of money on "special pans for induction. They are not currently offered in any UR versions. How are Heated Wells shipped to a fabricator? How are stainless steel adjustable and aluminum non-adjustable tubular stands for Strip Heaters (Foodwarmers) secured to a countertop? What's the weight limit for the induction glass tops? While 240 volt in 24kW through 45kW and 208 volt in 24kW through 39kW Booster Water Heaters may be ordered in single phase, consultation with the factory and written confirmation is required, due to high amperage in these types of applications. Prepared hot food (NOTE: The Heated Well is NOT a rethermalizer). Yes, the thermostat has a range of 90F - 200F (32C - 93C). What is the typical lead time for a Booster Water Heater NOT available in the Quick-Ship program? The Booster Water Heater must be installed in a horizontal position, with the base parallel to the floor and the inlet connection at the lowest point. Only 6kW, 7kW or 9kW Booster Water Heaters, 208 volt or 240 volt, are field convertible from single- to 3-phase, or vice versa. The wave is only about an inch deep above the surface of the cooktop, and is "fully captured" by the pan in place. Can the switches from multiple Strip Heaters (Foodwarmers) be housed in one Remote Control Enclosure (RMB)? Why can I only use one Glo-Ray Strip Heater (Foodwarmer) per Remote Control Enclosure (RMB)? This means that the units sizing selection should be checked for the intended altitude. It is also easy to replace the thermostat and heating elements, which are attached to the bottom assembly. What information needs to be included on an order for a Booster Water Heater? Yes, the Hatco Heated Well can be used wet or dry. It reduces water hammer, or the "banging noise" that results from quick closing solenoid valves on the dishwasher. Provided the local code accepts NFPA 54 requirements for venting a gas Booster Water Heater, the PMG-60 vents directly into the room in which it is installed.
- Satori Hudson Mist Tile
- Body Glove Paddle Board 15' Inflatable
- 1 Inch Copper Coil Tubing
- Napa Furniture Hillcrest Bedroom Suite
- Blue & White Talavera Tile
hatco glo-ray food warmer not working